Secured Trading Service

180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking

Shanghai Mida EV Power Co., Ltd.
  • Audited Supplier
  • 7 yrs

Contact Supplier

Product Highlights

  • 240kW DC Output: MD-EU-240KW supports compatible CCS2 vehicles at university campus parking areas; a separate 180kW model is available. Confirm vehicle charging acceptance and site capacity.
  • Dual CCS2 Campus Charging: Coordinate visitor, staff and fleet access with parking rules and operating schedules. Confirm power allocation, backend functions and the required payment configuration.
  • Network Connectivity: OCPP 1.6 / 2.0 with 4G, Wi-Fi and Ethernet options. Confirm backend compatibility and final configuration before commissioning.
  • Flexible Payment Options: Supports credit cards, RFID, and mobile QR code scanning via POS integration.
  • Clear User Interface: A 10.1-inch LCD guides drivers through charging at public parking locations.
  • Documented 240kW Cabinet: Dimensions 700 x 700 x 2000mm, net weight 580kg; package 750 x 750 x 2050mm and gross weight 600kg.
  • Full OEM/ODM Customization: Customizable cabinet color, logo, and user interface software for branding.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of 180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking

180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking pictures & photos
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking pictures & photos
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking pictures & photos
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking pictures & photos
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking pictures & photos
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking pictures & photos
180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
  • 180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
  • 180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
    180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
  • 180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
    180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
  • 180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
    180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
  • 180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
    180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
  • 180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
    180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
  • 180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking
    180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking

Find Similar Products

Product Description

 

DC Charging for University Campus Parking

MIDA 240kW dual CCS2 DC charging station supports university campus parking, with a separate 180kW option. Plan staff, visitor and fleet charging access while reviewing vehicle compatibility, parking duration, electrical capacity and backend functions.

180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking

240kW Charger Specifications

Parameter MD-EU-240KW
Rated output 240kW
Connector configuration Dual CCS2
DC voltage range 200-1000V
AC input 400Vac +/-10%, 3P+N+PE; 50/60Hz
Efficiency Greater than 95%
Power factor Greater than 0.99
Protection and cooling IP54; forced-air cooling
Display 10.1-inch LCD
Networking OCPP 1.6 / 2.0; 4G, Wi-Fi and Ethernet
Dimensions 700 x 700 x 2000mm
Net weight 580kg
Package dimensions 750 x 750 x 2050mm
Gross weight 600kg

The quoted model is MD-EU-240KW. A separate 180kW option is available. Confirm vehicle compatibility, access requirements and final configuration before ordering.

Match Charging Provision to Campus Demand

180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking

Review the different needs of visitors, staff vehicles and campus fleets. Parking duration and the energy required before departure should guide the charging plan. Use realistic vehicle demand and check how the DC charging station fits the wider site provision. Longer parking stays may call for a different charging approach from vehicles with short turnaround windows.

Confirm Dual CCS2 Vehicle Compatibility

180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking

Check the inlet type, operating voltage and charging curve for the vehicles expected to use the site. The 240kW rating represents total cabinet output. Actual power depends on vehicle acceptance and battery conditions, and simultaneous charging requires confirmed power allocation. Do not use the nameplate rating alone to promise a charging time.

Agree Campus Access and Parking Rules

180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking

Define who may use the charging bays, any charging windows and the operator responsible for assistance. Confirm the required authorization, payment and session records with the selected backend provider. OCPP support does not by itself guarantee every management function. Test the agreed driver workflow and prepare clear operating guidance before the campus site opens.

Design Safe Bays and Review Electrical Capacity

180kw 240kw Dual CCS2 DC Charging Station for University Campus Parking

Keep charging leads clear of walking routes and vehicle exits. Check inlet positions, cable reach and space for users to connect comfortably. Maintain service and emergency access around the floor-mounted DC charging station. A qualified installer should review foundations, supply capacity, protection and earthing, and verify network coverage at the cabinet location.

Frequently Asked Questions

1. Can campus users charge every EV at 240kW?

No. Confirm CCS2 and voltage compatibility. Actual power depends on vehicle charging acceptance, battery temperature, state of charge and available site capacity.

2. Is 240kW supplied by each connector?

No. 240kW is the total cabinet output. Confirm the final power allocation when two vehicles use the station simultaneously.

3. How can staff, visitors and fleet drivers share the station?

Agree access rules, charging windows and parking responsibilities. Confirm which authorization and payment functions are included in the chosen equipment and backend, then test the agreed workflow.

4. Does a long parking stay require DC fast charging?

Select charging provision from vehicle energy needs, parking duration and site capacity. Review the role of this DC station alongside the campus charging plan rather than assuming all parking bays require the same equipment.

5. What should the campus site designer check?

Review pedestrian routes, vehicle exits, inlet positions, cable reach and maintenance access. A qualified installer should confirm foundations, supply capacity, protection and earthing.

6. What are the cabinet and package dimensions?

For MD-EU-240KW, the cabinet is 70 x 70 x 200cm and 580kg net. The package is 75 x 75 x 205cm and 600kg gross. Confirm separate values for the 180kW option.

Campus Charging Project Information

Provide expected vehicle demand, parking duration, fleet schedules, site layout and electrical capacity. Confirm access requirements, simultaneous charging needs and the preferred backend platform. The Italy case video shows a bus-depot installation as an application reference; it does not verify the rating or exact configuration of this listing.

After Sales Service

Confirm warranty coverage, commissioning responsibilities, operator training and spare-parts arrangements before delivery. Provide the charger model, fault description and site network details when requesting technical support.

 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI244179". Items marked "verified" are certified.

Watch Video
Watch Video
Shanghai Mida EV Power Co., Ltd.
Shanghai Mida EV Power Co., Ltd.
Shanghai Mida EV Power Co., Ltd.
Shanghai Mida EV Power Co., Ltd.
Shanghai Mida EV Power Co., Ltd.
Shanghai Mida EV Power Co., Ltd.
Shanghai Mida EV Power Co., Ltd.
Shanghai Mida EV Power Co., Ltd.

About Our Factory & Business Background

Address
No.50 of Maoyuan Road, Fengxian District Shanghai 201400, China
verified Plant Area
410 square meters
verified Registered Capital
2,000,000 RMB
verified Terms of Payment
T/T
verified International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
10 pcs
verified Supply Chain Partners
8

Our Production Capability & Technical Expertise

Main Products
DC Charging Station, EV Charger Module, Liquid Cooled Power Module, Nacs & CCS1 & CCS2 & Gbt, Fast DC Charger, Wall Mounted DC Charger, Floor Standing Charging Station, DC Mobile EV Charger, EV Charging Products, Portable EV Charger
verified Customization Options
Customization from Samples, Full Customization, Customization from Designs, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2018-07-18
verified Export Year
5 years
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia, Domestic
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
6
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE
verified Cooperated with Fortune 500
No

FAQ

Which charging connector is supplied for this configuration?
This listing is configured with two CCS2 connectors. Vehicle compatibility and connector requirements should be confirmed before ordering.
How should a university plan shared charging access?
Review staff, visitor and campus fleet requirements, then agree parking access, charging windows and operator responsibilities. Confirm the authorization and payment functions included in the selected backend configuration, and test the user workflow before commissioning.
Does the charging station support direct credit card payments?
Yes, our chargers can be equipped with a specialized POS machine that supports major credit cards and contactless payments. It also supports RFID cards and QR code scanning via mobile apps for maximum user convenience.
Do you provide OEM/ODM services for branding and customization?
Yes, MIDA provides full OEM/ODM support. We can customize the cabinet color, apply your corporate logo, and even modify the user interface (UI) software to match your brand identity and operational needs.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now