• Uxr100040 40kw DC Charging Module
  • Uxr100040 40kw DC Charging Module
  • Uxr100040 40kw DC Charging Module
  • Uxr100040 40kw DC Charging Module
  • Uxr100040 40kw DC Charging Module
  • Uxr100040 40kw DC Charging Module

Uxr100040 40kw DC Charging Module

Condition: New
Output Current Range: 2-120A
Output Rating: 40kw
Peak Efficiency: ≥96%
Input Undervoltage Protection: 270±5VAC
Input Voltage Rage(AC): 285~475
Customization:
Manufacturer/Factory
Gold Member Since 2020

Suppliers with verified business licenses

Shanghai, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Customization from Samples
The supplier provides sample based customization services
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (14)

Basic Info.

Model NO.
UXR100040
Input Overvoltage Protection
495±5VAC
Output Constant Power Range
20kw with Output 250-1000VDC
Output Voltage Range
150-1000V DC
Purpose
for Replace/Repair
Soft Start Time
3-8s
Power
40kw
Transport Package
1PCS/Carton
Trademark
MIDA
Origin
Shanghai, China
Production Capacity
100 Carton/Cartons Per Month

Product Description



 

UXR100040 DC Charging Module 40kw Module DC Power Module

 

 

 

1.3.2Module Features

 

Ø Input voltage rage(AC):285~475

 

Ø Output voltage-adjustment range(DC):150~1000

 

Ø Working temp range:-30~+75ºC

 

Ø Above 1/3 load efficiency:≥95.6%

 

Ø High power factor:full load≥ 0.99

 

Ø Low THD:full load≤ 5%

 

Ø Low standby power loss:<13W

 

Ø Output constant power function:1000-250VDC   30KW

 

Ø Digital technology, current sharing imbalance for modules parallel<±5%

 

Ø CAN bus communication

 

Ø Quick plug and install

 

Ø Short circuit no damage

 

Ø Intelligent fan speed control

 

Ø Support parallel voltage regulation and current regulation function

 

Ø Equipped with perfect protection function

 

ü Input over/under voltage protection, input over current protection, phase loss protection

 

ü Output over voltage protection, current limit protection

 

ü Output prevent reverse irrigation(means "when the external voltage is higher than the output voltage of charging module, it will not cause damage to the module".)

 

ü Environment inspection & protection

 

Ø Group sharing function

 

ü Grouping modules is supported in the system. When grouping output, the module output power lines are required to be isolated from each other. Only CAN bus is connected between each module. The output voltage and current can be controlled independently between each group of modules, which can realize grouping current balance sharing output. It is suggested that the number of modules in each group≤24.

 

1.3.3Technical Specification

 

1, Input Features







Uxr100040 40kw DC Charging ModuleUxr100040 40kw DC Charging ModuleUxr100040 40kw DC Charging ModuleUxr100040 40kw DC Charging Module


























 

Item

Parameter

Remark

Working Voltage(AC)

285~475,rated voltage 380

See input voltage/output power curve 1.3.3-1

Input Frequency(HZ)

45~55

 

Power factor

Full load≥0.99

 

THD

Full load≤5%

 

Standby power loss

<13W

 

 

 

 

 

 

1.3.3-1input voltage/output power curve

 

2, Output Features

 




































































 

Item

Parameter

Remark

Output Voltage Range(DC)

150~1000

 

Max output current(A)

120

 

Output constant power interval

250~500VDC,500~1000VDC

 

Output current limit range

Max limit current is120A,limit current point can be set between 2~120A

Output voltage/current curve 1.3.3-2

Voltage Stabilization Accuracy

≤±0.5%

 

Current Stabilization Accuracy

≤±1%(load current is in the range of 20%~100%)

 

Effective value coefficient of output ripple

≤±0.5%

 

Current sharing imbalance for modules in parallel

≤±5%(parallel average current should be more than 5A)

 

Peak efficiency

≥95.5%

 

Soft start time(S)

3~8

 

When output, prevent current rewinding

Support

 

Communication Protocal

CAN

 

 

 

 

 

 

 

 

4, Environment Features

 























 

Item

Parameter

Remark

Working Temperature(ºC)

-30~75(above 55ºC output derating)

 

Storage Temperature(ºC)

-40~75

 

Relative Humidity

%5RH~95%RH  no condensation

 

 

5, Other Specification

 










































 

Item

Parameter

Remark

Insulation Strength

Input to enclosure

4200VDC  1 minute 5mA  No breakdown, no arcing

Input to output

4200VDC 1 minute  5mA  No breakdown, no arcing

output to enclosure

4200VDC 1 minute  5mA  No breakdown, no arcing

Input to communication

4200VDC 1 minute  5mA  No breakdown, no arcing

Output to communication

4200VDC 1 minute  5mA  No breakdown, no arcing

Communication to enclosure

1500VDC 1 minute  5mA  No breakdown, no arcing

Others

Protection Lever

IP20

Module Weight

≤16kg

 